Viscometer Bath - Senze-Instruments Benelux

Skip menu
Senze-Instruments BENELUX
Skip menu
Go to content
Process & Quality Control

Viscometer Bath

Laboratory Product > Water Baths
Skip menu
Digital Viscometry Bath GheatVisco

for the measurement of viscosity fluid samples through capillary tubes, as: Cannon-Fenske, Ubbelohde, …
Available also for chemical analysis, physical tests, crystallography, …

PLUS
• AG-System Control PRO: PID Digital Microprocessor, programmable
• Double Digital Display visualize simultaneously the set point and the inner temperature. Resolution +/- 0,1°C
• Platinum Probe PT100, Class A
• Range Temperature: From Amb. Temp. +5,0°C up to + 60,0°C for model with transparent tank or from +5,0°C up to + 100,0°C or +200,0°C for models in stainless steel
• Independent Safety Thermostat
• Circulation pump
• Cooling coil


The Cannon CT-518 series constant temperature bath accommodates viscometer tubes requiring a bath depth up to 18”
and provides reliable temperature control from 20 °C to 100 °C .
The unit accommodates up to 7 simultaneous viscosity determinations.
Common Applications :
  • Formulated oil analysis
  • Hydraulic oil analysis
  • Additive analysis
  • Marine fuel testing
  • Base stock analysis
  • Light and heavy fuel testing
  • Waxes/paraffin  
  • Crude oil testing
  • Glycols
CT-518 Constant Temperature Bath (230 V)
Ref # 9726-A19

For Kinematic Viscosity from 20 °C to 100 °C.
he CT-518 series constant temperature bath accommodates viscometer tubes requiring a bath depth up to 18" and provides reliable temperature control from 20 °C to 100 °C .
The unit accommodates up to 7 simultaneous viscosity determinations.
Conforms to test methods ASTM D445/D446 and ISO 3104/3105.

SPECIFICATIONS
UNIT WEIGHT   :  22 kg
DIMENSIONS (W X D X H) :  40.7 cm × 36.2 cm × 76.2 cm
SHIPPING DIMENSIONS (W X D X H) :  76.2 cm × 58.4 cm × 55.9 cm
SHIPPING WEIGHT (WITH ALL ITEMS) : 36.3 kg
SAMPLE CAPACITY :  7
TEMPERATURE RANGE AND ACCURACY :  20 °C to 100 °C,± 0.01 °C*,*
                                                                                                   Test temperatures < 40 °C and high ambient temperature test environments
                                                                                                   require an optional bath cooler
OPERATING CONDITIONS  :   15 °C to 30 °C,10% to 75% relative humidity (non-condensing),Installation Category II;
                                                                    Pollution Degree 2
ELECTRICAL SPECIFICATIONS  :   120 Vac,50/60 Hz; 240 Vac,50/60 Hz; 1000 watts power consumption
COMPLIANCE  :  CE Mark; EMC directive (2004/108/EC); Low voltage directive (2006/95/EC);
                                      HI-POT (1900 Vdc,60 sec.); ROHS
BATH VOLUME   :  23.8 L (6.3 gal)
BATH HEIGHT   :45,72 cm




Back to content