Wet-Bulb/Dry-Bulb system

Temperature > rH Monitoring
Skip menu
Back to the TEMPERATURE MENU
LCS140 Lethality Compliance System

Need to record humidity at high temperatures?

Look no further than the
LCS140 WetBulb/Dry-Bulb system.

Ditch the complexity of calculating with a psychrometer, the LCS140 coupled with the MadgeTech 4 Software does all the work for you!

Capable of withstanding temperatures from -40°C to +140°C, the dual probe LCS140 takes wet-bulb and dry-bulb readings simultaneously to determine the amount of humidity present.

The LCS140 Includes:
• LCS140 Dual Probe Data Logger
• Reservoir Bottle (recommended to use distilled water only)
• Wet Bulb Socks
• Hanging Fixture

The LCS140 is compatible with the latest MadgeTech 4 Software making starting, stopping, and downloading simple and easy.
Graphical, tabular, and summary data is provided for analysis and can be viewed as customizable engineering units.
SPECIFICATIONS

TEMPERATURE
Temperature Sensor                Rigid RTD Probe
Temperature Range                 -40 °C to +140 °C
Resolution                                     0.01 °C
Calibrated Accuracy                ±0.1 °C

GENERAL
Start Modes                                    Software programmable immediate start or delay start up to 18 months in advance
Stop Modes                                    Manual or Timed (specific date and time)
Memory                                            32,767 readings
Password Protection                 An optional password may be programmed into the device to restrict access to
                                                               configuration options. Data may be read out with the password.
Readings in Trigger Settings Mode                  16,383 readings
Trigger Settings                            High and Low limits may be set.
                                                              Once data meets or exceed sets limits, the device will record to memory.
                                                               Bi-level start and stop triggers can also be programmed.
                                                               Users can specify the number of readings to take after the device triggers.
                                                                (Triggering on channel #1 only)
Wrap Around                                  Yes
Calibration                                        Digital calibration through software
Calibration Date                            Automatically recorded within device